RC Assurance 
                 
         


RC Assurance™ is a clip designed for resilient channels. The product acts as an
impenetrable washer that puts extra space between the channel and the joist. The snap on clip works with any resilient channel but is specifically designed for use with RC Deluxe from Dietrich. Developed a number of decades ago, resilient channels are a staple in the multi-family industry. There are some issues with Resilient Channel installation. The typical design and UL assembly call for a fastener of 1.0”. The typical installation utilizes a 1.25” or 1.5” fastener, mostly to aid in the “GRAB” of the screw to the channel. This minor modification assures that 15% of the connections will be compromised and that the performance of the system will short circuit the low frequency transmission effectiveness of the system. Now that lab tested 52 becomes a field 42. The resilient channel needs another 0.375” to assure that connections are      
                                                    limited between the gypsum board and the joist assembly.  RC ASSURANCE provides
                                                    that space.


Applications

• Multi-Family Construction:  Apartments & Condominiums
• Floor Assemblies & Wall Assemblies
• Designed for the most popular channel – RC Deluxe by Dietrich Industries
• Single or double layer gypsum board applications
• Over 27 approved UL listings
• With every joist type: metal, open web, “I” joist design & nominal 2” lumber


 
   Downloads:

   Data Sheet
   Installation Instructions
   Guide Specifications
   RC Assurance™
Brochure
Features & Benefits

• Excellent performance at the lowest, below 400 Hz
• UL Listed & Approved
• Hardened Steel that can not be penetrated so extra long screws would not work in the application
• Push down flange that prevents channel “ride”
• Intersection of the channel & joist are protected from short circuiting
• Ease in installation, snap on design & no laser alignment like other clips
• Performance equal to expensive Hat channel systems

 Wall Assembly - Wood
 
  
            
             
              Sound Transmission Loss Test Report No. TL07-331


              STC - 52

              Construction (Left to Right)
                    • 1 Layer 5/8” Gypsum Board
                    • 3 1/2” Batt Insulation
                    • 2x4 Wood Studs at 16” O.C.
                    • RC Assurance Clip
                    • Resilient Channel
                    • 1 Layer 5/8” Gypsum Board









              
               Sound Transmission Loss Test Report No. TL07-332

               STC - 57

               Construction (Left to Right)
                    • 2 Layers 5/8” Gypsum Board
                    • 3 1/2” Batt Insulation
                    • 2x4 Wood Studs at 16” O.C.
                    • RC Assurance Clip
                    • Resilient Channel
                    • 1 Layer 5/8” Gypsum Board







                Sound Transmission Loss Test Report No. TL07-333

                STC - 61

                Construction (Left to Right)
                    • 2 Layers 5/8” Gypsum Board
                    • 3 1/2” Batt Insulation
                    • 2x4 Wood Studs at 16” O.C.
                    • RC Assurance Clip
                    • Resilient Channel
                    • 2 Layers 5/8” Gypsum Board







                Sound Transmission Loss Test Report No. TL07-343

                STC - 52

                Construction  (Left to Right)
                    •  1 Layer 5/8” Gypsum Board
                    •  6” Batt Insulation
                    •  2x6 Wood Studs at 16” O.C.
                    •  RC Assurance Clip
                    •  Resilient Channel
                    •  1 Layer 5/8” Gypsum Board







                Sound Transmission Loss Test Report No. TL07-344


                STC - 57

                Construction (Left to Right)
                    • 2 Layers 5/8” Gypsum Board
                    • 6” Batt Insulation
                    • 2x6 Wood Studs at 16” O.C.
                    • RC Assurance Clip
                    • Resilient Channel
                    • 1 Layer 5/8” Gypsum Board







                Sound Transmission Loss Test Report No. TL07-345

                STC - 61

                Construction (Left to Right)
                    • 2 Layers 5/8” Gypsum Board
                    • 6” Batt Insulation
                    • 2x6 Wood Studs at 16” O.C.
                    • RC Assurance Clip
                    • Resilient Channel
                    • 2 Layers 5/8” Gypsum Board





 Wall Assembly - Steel




               
Sound Transmission Loss Test Report No. TL07-325

                STC - 40

                Construction (Left to Right)
                     • 1 Layer 5/8” Gypsum Board
                     • 3 1/2” Batt Insulation
                     • 3 5/8” 20 Gauge Metal at 16” O.C.
                     • 1 Layer 5/8” Gypsum Board









                Sound Transmission Loss Test Report No. TL07-328

                STC - 54

                Construction (Left to Right)
                     • 2 Layers 5/8” Gypsum Board
                     • 3 1/2” Batt Insulation
                     • 3 5/8” 20 Gauge Metal at 16” O.C.
                     • RC Assurance Clip
                     • Resilient Channel
                     • 1 Layer 5/8” Gypsum Board







                Sound Transmission Loss Test Report No. TL07-329

                STC - 59

                Construction (Left to Right)
                     • 2 Layers 5/8” Gypsum Board
                     • 3 1/2” Batt Insulation
                     • 3 5/8” 20 Gauge Metal at 16” O.C.
                     • RC Assurance Clip
                     • Resilient Channel
                     • 2 Layers 5/8” Gypsum Board